๐ Recent Shifts โ quick switch
Date & Shift
2026-06-12
Night โ Team A
TOTAL HC&FC REJECT
26
Units
H&F REJECTION %
5.57%
of total production
NDT REJECTION %
4.93%
of total production
| No | Observation | Status |
| 1 |
Gas welding cylinder not on wright location |
Medium Risk |
| 2 |
Lath machine cover broken need to fix |
Low Risk |
| 3 |
fire extinguisher not on location |
Low Risk |
| Furnace |
Mass Received (Ton) |
Consumed (Ton) |
Metal Added (Ton) |
Mass End of Shift (Ton) |
Remarks |
| HA
min: 28T
|
30.60 |
6.60 |
0.00 |
24.00 |
โ |
| HC
min: 24T
|
29.90 |
1.90 |
0.00 |
28.00 |
โ |
| SWM1
|
0.00 |
0.00 |
0.00 |
0.00 |
โ |
| SWM2
|
0.00 |
0.00 |
0.00 |
0.00 |
โ |
| Stage | Condition | Comments |
| Received |
Bad |
work is going on for repair from HA to HC half complete From HA to SWM2 not start yet |
| Hand Over |
Bad |
work is going on for repair from HA to HC half complete From HA to SWM2 not start yet |
| M/C No. |
Status |
Mold Type |
NDT OK |
HC & FC Reject |
NDT Reject |
Total |
Rejection % |
H&F Rej % |
NDT Rej % |
Remarks |
| 5 |
Running |
cv9822 |
12 |
5 |
0 |
17 |
29.4% |
29.4% |
0.0% |
start by 11:30 |
| 6 |
Running |
smx201-22 m4 |
73 |
5 |
5 |
83 |
12.1% |
6.0% |
6.0% |
โ |
| 7 |
Running |
640-16" |
105 |
3 |
2 |
110 |
4.6% |
2.7% |
1.8% |
โ |
| 8 |
Running |
640-15" |
96 |
4 |
12 |
112 |
14.3% |
3.6% |
10.7% |
โ |
| 16 |
Running |
640-17" |
95 |
5 |
3 |
103 |
7.8% |
4.9% |
2.9% |
โ |
| 18 |
Running |
ca90-22 |
37 |
4 |
1 |
42 |
11.9% |
9.5% |
2.4% |
โ |
| TOTAL PRODUCTION |
467 |
โ | โ | โ | โ |
| TOTAL REJECTION |
49 |
10.5% |
5.6% |
4.9% |
โ |
| M/C | Issue | DownTime (min) | Action Taken | Pending Action | Responsible | Status | Odoo Notification |
| laser mark 2 |
scaner |
40 min |
maintenance team |
no |
maintenance team |
Closed |
yes |
| S.D no4 |
error |
60 min |
maintenance team |
no |
maintenance team |
Closed |
yes |
| Die Model | Status | Remarks |
| cv98-20- M2 service done ready for work |
Completed |
โ |
| cv40-22-m1 service done ready for work |
Completed |
โ |