Report #26 โ Submitted 2026-06-14 19:11:59
| No | Observation | Status |
|---|---|---|
| 1 | glass broken on D2 | High Risk |
| Furnace | Mass Received (Ton) | Consumed (Ton) | Metal Added (Ton) | Mass End of Shift (Ton) | Remarks |
|---|---|---|---|---|---|
| HA
min: 28T
|
20.16 โ Below minimum
|
-11.70 | 0.00 | 31.86 | sllicone added 6 pm |
| HC
min: 24T
|
25.77 | -4.59 | 0.00 | 30.36 | โ |
| SWM1 | 0.00 | 0.00 | 0.00 | 0.00 | โ |
| SWM2 | 0.00 | 0.00 | 0.00 | 0.00 | โ |
| Stage | Condition | Comments |
|---|---|---|
| Received | Bad | HA to SWM2 bad ( metal solidify) |
| Hand Over | Bad | HA to SWM2 bad ( metal solidify) |
| M/C No. | Status | Mold Type | NDT OK | HC & FC Reject | NDT Reject | Total | Rejection % | H&F Rej % | NDT Rej % | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
| 7 | Stopped | 640-16 | 24 | 3 | 5 | 32 | 25.0% | 9.4% | 15.6% | stopped due to melting forklift issue |
| 16 | Stopped | 640-17 | 44 | 2 | 0 | 46 | 4.4% | 4.4% | 0.0% | stopped due to melting forklift issue |
| 18 | Stopped | CA91-22 | 24 | 2 | 1 | 27 | 11.1% | 7.4% | 3.7% | stopped due to melting forklift issue |
| TOTAL PRODUCTION | 105 | โ | โ | โ | โ | |||||
| TOTAL REJECTION | 13 | 12.4% | 6.7% | 5.7% | โ | |||||
| M/C | Issue | DownTime (min) | Action Taken | Pending Action | Responsible | Status | Odoo Notification |
|---|---|---|---|---|---|---|---|
| LDPC5 | robo gribber issue | 300 min | โ | to be fixed | maintance | Closed | โ |
| LDPC6 | robo gribber issue | 300 min | โ | to be fixed | maintance | Closed | โ |
| LPDC8 | ram fast movment damging raiser tube | 400 min | โ | to be fixed | maintance | Open | โ |
| Die Model | Status | Remarks |
|---|---|---|
| 640-16'' | Completed | โ |
all machined stopped due to forklift issues forklift D1 no ac blet broken no radiator cap D2 glass broken , fixed , silicone to be cured