๐Ÿ• Recent Shifts โ€” quick switch
Date & Shift
2026-06-20
Day โ€” Team B
TOTAL NDT OK
179
Units
TOTAL HC&FC REJECT
12
Units
H&F REJECTION %
5.80%
of total production
NDT REJECTION %
7.73%
of total production
DOWNTIME (min)
0
min
๐Ÿ“‹
GENERAL INFORMATION
Date:
2026-06-20
Shift:
Day
Supervisor:
Mohammed AL roshdi
Team:
B
Total Attendance:
17
Total Absent:
5
โš ๏ธ
SAFETY OBSERVATIONS
NoObservationStatus
1 The work site is very dirty Medium Risk
๐Ÿ”ฅ
FURNACE STATUS
Furnace Mass Received (Ton) Consumed (Ton) Metal Added (Ton) Mass End of Shift (Ton) Remarks
HA
min: 28T
31,440.00 -2,910.00 0.00 34,350.00 โ€”
HC
min: 24T
19,200.00 4,380.00 0.00 14,820.00 โ€”
SWM1 0.00 0.00 0.00 0.00 โ€”
SWM2 0.00 0.00 0.00 0.00 โ€”
๐ŸŒŠ
LAUNDER CONDITION
StageConditionComments
Received Good โ€”
Hand Over Good โ€”
๐Ÿญ
CASTING PRODUCTION
M/C No. Status Mold Type NDT OK HC & FC Reject NDT Reject Total Rejection % H&F Rej % NDT Rej % Remarks
4 Stopped 640-16 m1 46 2 2 50 8.0% 4.0% 4.0% โ€”
7 Stopped 640-17 m2 39 2 2 43 9.3% 4.7% 4.7% โ€”
14 Stopped R62-18 15 4 1 20 25.0% 20.0% 5.0% โ€”
15 Stopped 640-15 34 2 9 45 24.4% 4.4% 20.0% โ€”
16 Stopped 640-16 m2 45 2 2 49 8.2% 4.1% 4.1% โ€”
TOTAL PRODUCTION 207 โ€”โ€”โ€”โ€”
TOTAL REJECTION 28 13.5% 5.8% 7.7% โ€”
๐Ÿ”ง
MACHINE BREAKDOWN REPORT
M/CIssueDownTime (min)Action TakenPending ActionResponsibleStatusOdoo Notification
โ€” No breakdowns recorded โ€”
๐Ÿ› ๏ธ
DIE MAINTENANCE PLAN
Die ModelStatusRemarks
640-17 m2 Completed โ€”
๐Ÿ“
ADDITIONAL REMARKS

HA pump jammed. HC pump broken

โœ๏ธ Start a New Report