Report #84 โ Submitted 2026-07-31 21:53:45
| No | Observation | Status |
|---|---|---|
| 1 | Change safety wire for machine | Closed |
| Furnace | Mass Received (Ton) | Consumed (Ton) | Metal Added (Ton) | Mass End of Shift (Ton) | Remarks |
|---|---|---|---|---|---|
| HA
min: 28T
|
16.00 โ Below minimum
|
16.00 | 0.00 | 0.00 | โ |
| HC
min: 24T
|
19.60 โ Below minimum
|
22.60 | 0.00 | -3.00 | โ |
| SWM1 | 30.00 | 25.00 | 0.00 | 5.00 | โ |
| SWM2 | 0.00 | 0.00 | 0.00 | 0.00 | โ |
| Stage | Condition | Comments |
|---|---|---|
| Received | Good | โ |
| Hand Over | Good | โ |
| M/C No. | Status | Mold Type | NDT OK | HC & FC Reject | NDT Reject | Total | Rejection % | H&F Rej % | NDT Rej % | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
| 4 | Running | 640-17 M2 | 90 | 6 | 6 | 102 | 11.8% | 5.9% | 5.9% | โ |
| 5 | Running | Cv98-20 | 59 | 5 | 3 | 67 | 11.9% | 7.5% | 4.5% | โ |
| 6 | Running | Smx201-22 M5 | 34 | 7 | 1 | 42 | 19.1% | 16.7% | 2.4% | โ |
| 14 | Running | 640-16 M1 | 62 | 7 | 3 | 72 | 13.9% | 9.7% | 4.2% | โ |
| 15 | Running | 640-17 M1 | 90 | 5 | 3 | 98 | 8.2% | 5.1% | 3.1% | โ |
| 16 | Running | 640-16 M2 | 90 | 6 | 7 | 103 | 12.6% | 5.8% | 6.8% | โ |
| TOTAL PRODUCTION | 484 | โ | โ | โ | โ | |||||
| TOTAL REJECTION | 59 | 12.2% | 7.4% | 4.8% | โ | |||||
| M/C | Issue | DownTime (min) | Action Taken | Pending Action | Responsible | Status | Odoo Notification |
|---|---|---|---|---|---|---|---|
| โ No breakdowns recorded โ | |||||||
| Die Model | Status | Remarks |
|---|---|---|
| 640-15 m1 5H | Completed | โ |
Forklift D1 needs to deep maintenance , because the radiator very dirty .. All selected molde have been moved outside the die maintenance